These data loggers are ideal for monitoring temperature(or humidity) in transport, storage, testing process, etc.
User needs to install USB driver and DGraph software that run under Windows XP, Vista, 7, 8 or 10(32 bit and 64 bit Versions). and use the software to setup sample rate, high/low alarm limit and start/stop method , and download data to PC, etc. And then view, analyse and print the data, or export other file formats(txt, xsl, csv, bmp, jpg).
Especially, in professional applications, user can set access password, name each channel, enable/disable specified channel, input calibration data for each channel, disable LED indication for saving power, and select sample mode(Instant, Average, Maximum and Minimum), etc.
Features and Functions
USB interface directly communicate with PC
Free software to setup, download and analyze data
Set access password fo each data logger
LCD indicates readings, status and alarm
LED indicates Alarm and status
Start method: immediately, button, start at time
Stop method: button, memory full, points finished
Support FIFO cycle recording mode
Replaceable lithium battery and data not lost if exhausted
Two point calibration for each channelAlarm limit settings for all channels
Support to create compound graph
Support to create new unit easily
Name each channel and enable/disable it
User configurable graph settings
Support that several loggers shown together
Disable LCD or LED to save power consumption
To save as txt, xsl, csv, bmp, jpg
Applications
These data loggers are used mainly to monitor and verify temperature(or humidity) sensitive goods, equipment or areas. Example: Cold Chain, Refrigeration, Transportations, Warehouse, HVAC, Food&Pharmaceutical.
Specifications and Selection Guide
Model | SSN-11 | SSN-10 | SSN-13 | SSN-12 | SSN-11E | SSN-10E | SSN-13E | SSN-12E
|
LCD | YES | NO | YES | NO | YES | NO | YES | NO |
Channels | Temperature | Temperature
| Temperature
| Temperature
| Temperature (ext.) | Temperature (ext.) | Temperature (ext.) | Temperature (ext.) |
Range | -35~80℃ | -35~80℃ | -35~80℃ | -35~80℃ | -40~125℃ | -40~125℃ | -40~125℃ | -40~125℃ |
Accuracy | ±0.5℃ | ±0.5℃ | ±0.3℃ | ±0.3℃ | ±0.5℃ | ±0.5℃ | ±0.3℃ | ±0.3℃ |
Resolution | 0.1℃ | 0.1℃ | 0.1℃ | 0.1℃ | 0.1℃ | 0.1℃ | 0.1℃ | 0.1℃ |
Operation environment | -35~80℃ | -35~80℃ | -35~80℃ | -35~80℃ | -35~80℃ | -35~80℃ | -35~80℃ | -35~80℃ |
Storage environment | -35~80℃ | -35~80℃ | -35~80℃ | -35~80℃ | -35~80℃ | -35~80℃ | -35~80℃ | -35~80℃ |
Size(mm) weight | 120X37X23 67g | 120X37X23 67g | 120X37X23 67g | 120X37X23 67g | 120X37X23 67g | 120X37X23 67g | 120X37X23 67g | 120X37X23 67g |
Protection Class | IP54
| IP54 | IP54 | IP54 | IP40 | IP40 | IP40 | IP40 |
Interface: USB(it can power for device) Battery: lithium battery Certificate and standard: CE, ROHS, REACH Readings memory(total for all channels): 32000 Software:DGraph(free) OS:windows xp/7/8/10/vista 32bits/64bits |